| Nama Pengarang | : | J.M. Payne |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 811-823 |
| Abstraksi Narasi | : | A new generation of low-noise, dual-polarization heterodyne receivers covering all atmospheric windows between 68 and 300 GHz has been developed for the 12-m telescope on Kitt Peak, AZ, operated by the National Radio Astronomy Observatory (NRAO). A modular approach to the receiver construction has been used. Each receiver channel is constructed as a self-contained insert which is mounted in a dewar equipped with a closed-cycle 4 K refrigerator capable of cooling up to eight inserts, thereby enabling several frequency bands to be contained within one dewar. The telescope and receiver optics are so arranged that switching between frequency bands may be accomplished rapidly by rotating the optical elements placed in the signal path. Single-sideband noise temperatures ranging from 50 to 400 K are obtained across the frequency range. |
| Nama Pengarang | : | - |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 796-810 |
| Abstraksi Narasi | : | The Deep-Space Network (DSN) includes world-wide networks of 26-, 34- and 70-m antennas in Australia, Spain, and the USA. Ruby masers are used on the 34and 70-m antennas to maximize the system operating noise temperature and thereby maximize the DSN receiving system figure of merit, antenna gain divided by system operating noise temperature. These systems are used for deep-space telecommunications, solar system radar, and radio astronomy. Cavity, traveling-wave, and reflected-wave maser designs and performance characteristics from 960 MHz to 34 GHz are summarized. Effective noise temperatures of ruby masers are addressed with emphasis on a 33.68-GHz maser where quantum noise is a major source of noise. |
| Nama Pengarang | : | - |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 788-795 |
| Abstraksi Narasi | : | Advances in fiber-optic technology have made it possible to develop a new technique to isolate and measure the frequency stability of a large beam-waveguide (BWG) antenna. Through the use of the technique described in the paper, at both 46.5/spl deg/ and 37/spl deg/ elevation angles, under good weather conditions, the degradation of the the fractional frequency stability of signals passing through the antenna path was measured to be between 1.3 and 2.2/spl times/10/sup -15/ for sampling intervals of 1024 s. These stability values apply to the portion of the antenna that includes the main reflector, subreflector, tripod legs, and six BWG mirrors. These test results are believed to be the first successful fractional frequency stability measurements made on the microwave optics portion of a large antenna to a level of 1 or 2 parts in 10/sup 15/. |
| Nama Pengarang | : | C.T. Stelzried |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 776-787 |
| Abstraksi Narasi | : | The NASA Deep Space Network (DSN) has a long history of providing large parabolic dish antennas with precision surfaces, low-loss feeds, and ultra-low noise amplifiers for deep-space telecommunications. To realize the benefits of high sensitivity, it is important that receiving systems are accurately calibrated and monitored to maintain peak performance. A method is described to measure system performance and to calibrate the receiving system using procedures, software, and commercial instruments that are easy to implement and efficient to use. The utility of the measurement procedures and the precision of the receiver calibration technique were demonstrated by performing tests at Ka-band (32 and 33.68 GHz) frequencies at Goldstone on a 34-m beam-waveguide antenna. Observations of multiple calibration radio sources are used to measure the dependence of antenna gain and system noise temperature on source elevation and derive the performance parameters. The experimental results described illustrate some of the ways that receiving system nonlinearity can negatively impact system performance. A simple radiometer calibration technique and analysis provide quantitative information that enables the system engineer to adjust and linearize the receiving system. When that is not practical, the experimenter or the operator can apply connection coefficients to the measured values of system noise temperature and thereby compensate for the receiving system nonlinearity. |
| Nama Pengarang | : | R.D. Norrod |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 768-775 |
| Abstraksi Narasi | : | This paper discusses the design, construction, and measured performance of dual-band, dual-polarization, prime focus receiver systems used on three antennas at the NRAO facility in Green Bank, WV. The receivers operate at Sand X-bands near 2.3 and 8.4 GHz. Described is the development of a new dualband feed horn, a cryogenics package with waveguide input ports using HEMT low-noise amplifiers, and a receiver system using optical fiber microwave links to transmit frequency reference and IF signals. Measured performance of major components and the overall installed system is given. |
| Nama Pengarang | : | C.R. Lawrence |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 763-767 |
| Abstraksi Narasi | : | The 5.5-m telescope of the Owens Valley Radio Observatory is used for highly sensitive measurements of the cosmic microwave background radiation, which are easily contaminated by ground spillover. The authors describe the modifications made to the secondary mirror support structure that reduced the total ground pickup of the antenna from 27 to 9 K and decreased the peak differential ground pickup for the observing technique from 43 mK to 140 /spl mu/K. This was achieved by reducing the physical obstruction, arranging the support leg angles to minimize direct reflections, and installing radiation baffles to control the direction of the reflection or scatter lobes. |
| Nama Pengarang | : | C.E. Mayer |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 756-762 |
| Abstraksi Narasi | : | Describes the measurement of the surface shape of the primary reflector of the NRAO 12-m radio telescope and the use of the measurements to machine the shape of a secondary mirror to compensate for the primary reflector errors. The method known as holography was used with the 38.04-GHz transmitter on the geosynchronous Lincoln Experimental Satellite to map the main reflector. The machining of the secondary compensated for the errors in the primary shape, and as a result, at 345 GHz, the axial gain of the instrument was increased by about 50% and the antenna pattern correspondingly improved. |
| Nama Pengarang | : | - |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 742-755 |
| Abstraksi Narasi | : | The Haystack 37-m radio telescope has been upgraded for operation at frequencies up to 115 GHz. A unique deformable subreflector with active actuator control has been developed to correct for gravitational distortion effects including astigmatism and deflections associated with the particular reflector surface. Active thermal compensation of the surface has also been implemented to conduct for both thermal lag effects and circularly symmetric gravitational deviations. Holographic mapping of the antenna surface deviations was achieved using 12-GHz geostationary satellite transmissions, which required the use of special techniques to correct for diffraction and multiple reflection effects involving the space-frame radome that covers the antenna. Realignment of the antenna surface utilized a finite-element structural model to translate surface deviations to motions of the unusual adjustment mechanisms on the antenna. The currently measured rms surface deviation (Dec. 23, 1992) is 210 /spl mu/m. The telescope has been equipped with a two-channel cryogenically cooled 3-mm SIS receiver, covering the range from 84 to 115 GHz. A new flexible digital spectrometer has been constructed for spectral line astronomy. Configurations can range from a widest bandwidth coverage of 160 MHz at 512 lags to 0.66 MHz at 4096 lags. Examples are given of surface holographic maps and radio measurements of aperture efficiency, pointing, and other performance parameters. |
| Nama Pengarang | : | M.J. Brenner |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 734-741 |
| Abstraksi Narasi | : | A 20.1-m-diameter radome enclosed radio telescope, built by Electronic Space Systems Corporation (ESSCO) at the Onsala Space Observatory (OSO) near Gothenberg, Sweden, in 1975, was upgraded by ESSCO in 1992 for improved operation at 115 GHz, increasing the system aperture efficiency from 20% to 40% at this higher frequency. Electrical gain measurements confirm geometric optics predictions of efficiency and improved antenna patterns. The upgrade included replacement of the two inner reflector panel rows with 31-/spl mu/m panels, stiffening the reflector backstructure based on finite-element structural analysis for a measured rms gravity deformation of 59 /spl mu/m in the 25/spl deg/ to 70/spl deg/ elevation range, and optical alignment of the reflector surface to 58 /spl mu/m rms accuracy. This alignment accuracy of approximately 1/345000 of the reflector diameter was accomplished with an electronic angle-measuring theodolite and digital radial strap gauges. Data were downloaded in real time to an on-line portable computer performing surface metrology calculations. Graphical data are presented that compare computer predictions of reflector backstructure gravity deformations to optical measurements, which proved crucial in achieving the stringent alignment accuracies. Measured antenna efficiency data before and after the upgrade are included. |
| Nama Pengarang | : | N. Ukita |
| Nama Majalah/Jurnal | : | Proceedings of the IEEE |
| Volume / Nomor Edisi | : | 82-5, MAY (No. 5) |
| Nomor Halaman | : | 725-733 |
| Abstraksi Narasi | : | The Nobeyama 45-m telescope has been upgraded for higher frequency and higher sensitivity observations. The surface accuracy of the antenna was improved from 0.2 mm rms to 65 /spl mu/m rms using a radio holography method at the prime focus. Pointing accuracy was also improved by replacing a large Gregorian subreflector cabin with a smaller cassegrain subreflector in 1985 to reduce wind loading effects, and by installation of a new master collimator with multi-pole resolvers which were calibrated to an accuracy of 0.4 arcsec rms in 1988. Four SIS receivers using Nb/AlO/sub x//Nb array junctions are now available on the telescope for 40, 80, 100, and 150-GHz bands. These receivers achieved quite low noise and wide-band tunability. The 2/spl times/2 multi-beam receiver for 115 GHz is very powerful for mapping observations. These improvements of telescope performance and these receivers have significantly increased the astronomical observation capability of the telescope in the wide frequency range of 40 to 150 GHz. |